Automated Cardiac Arrest Detection Incorporated in a Wristband: First Experience with Spontaneous Cardiac Arrest Detection
CIRCULATION(2024)
Radboud University Medical Center
Abstract
Introduction: Survival from out-of-hospital cardiac arrest depends on immediate recognition and early cardiopulmonary resuscitation. Especially for unwitnessed cardiac arrest, survival chances are poor due to delays in receiving help. Automated cardiac arrest detection using wearables could facilitate early help. In the DETECT-1 study, an algorithm for circulatory arrest detection was developed using wrist-derived photoplethysmography (PPG) from patients with induced circulatory arrest, yielding 98% sensitivity. Next step is the validation of this algorithm in spontaneous cardiac arrest events. Goal: This study presents the first experience with the PPG algorithm for cardiac arrest detection in hospitalized patients with spontaneous cardiac arrest. Methods: The study population consisted of patients who underwent transcatheter aortic valve implantation (TAVI) complicated by an episode of cardiac arrest, and patients admitted to the intensive care unit (ICU) in whom life sustaining treatment was withdrawn, while wearing the PPG wristband. Continuous ECG, arterial blood pressure data, and/or procedural logs were used as reference standard. The developed PPG algorithm for cardiac arrest detection was used to study sensitivity for cardiac arrest detection. Additionally, the mean arterial pressure (MAP) and pulse pressure, determined from the arterial blood pressure at the time of the algorithm’s cardiac arrest alarm, were analyzed. Results: A cardiac arrest occurred in 15 patients (9 TAVI patients and 6 ICU patients), of whom 2 had ventricular fibrillation, 11 pulseless electrical activity (Figure 1), and 2 asystole. Cardiac arrest was successfully detected in 14 out of the 15 patients, yielding a sensitivity of 93% (95% CI 66-100%). The false negative alarm was related to noisy PPG signal resulting from the immediate resuscitative interventions of the medical team. PPG data were identified as cardiac arrest at a median MAP of 37 mmHg (IQR 26-55 mmHg) and a median pulse pressure of 16 mmHg (IQR 6-18 mmHg). There were no false positive cardiac arrest alarms. Conclusion: The PPG algorithm successfully detected all but one cardiac arrests, which holds promise for future implementation of wristband-based cardiac arrest detection. Moreover, there were no false positive alarms. As a the next step, the PPG algorithm needs to be validated in a larger sample of cardiac arrest events and potential false positive alarms need to be studied thoroughly during daily life use.
MoreTranslated text
求助PDF
上传PDF
View via Publisher
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
- Pretraining has recently greatly promoted the development of natural language processing (NLP)
- We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
- We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
- The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
- Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example

Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined