BackgroundMobile C-arms may be used in fixed locations, and it is recommended that qualified experts evaluate structural shielding.PurposeTo assess clinical workload distributions for mobile C-arms used in gastrointestinal endoscopy and determine the Archer equation parameters for the C-arm beam spectra.MethodsConsecutive (30 months) gastrointestinal endoscopic procedures on two Cios Alpha systems (Siemens) were retrospectively analyzed. X-ray tube voltage, tube current-time product, reference point air kerma (Ka,r), air kerma-area product (PKA), and fluoroscopic time were examined. The primary beam half-value layer (HVL) was measured with an ionization chamber and aluminum 1100 plates. Stray radiation fraction at 1 m from a scattering source (ACR R/F phantom) was directly measured. Monte Carlo (Geant4) simulation was performed to calculate the transmission of broad X-ray beams through lead, concrete, gypsum, and steel, with X-ray HVLs matching those of the C-arm X-ray beam. The transmission data were fitted to the Archer equation.ResultsThe number of procedures (3509) was equivalent to 13.48 procedures per room per week. Dose quantities were 54.8 mGy (Ka,r), 18.3 Gy center dot cm2 (PKA), and 7.8 min (fluoroscopic time) per procedure. X-ray beam irradiation events were recorded for 2906 (82.8%) procedures with 160,009 events, whose mA-minute weighted tube voltage was 91.0 kV and the workload was 0.68 mA-minute per procedure. The two rooms had a significant difference in the number of procedures per week, 17.3 (29) [mean (maximum)] and 9.6 (16), respectively. The stray radiation fraction was 9.7x10-4 (80 kV) and 1.25x10-3 (120 kV). Transmission fitting parameters were provided for the tube voltage (on average, 90 kV; high end, 120 kV) of the C-arm.ConclusionsThis work provides workload and transmission data for mobile C-arm fluoroscopy in gastrointestinal endoscopy, which indicates a need for structural shielding evaluation of the procedure rooms.
More
Translated text
Key words
fluoroscopy,gastrointestinal endoscopy,mobile C-arm,radiation shielding,transmission data,workload
求助PDF
上传PDF
Bibtex
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
  • Pretraining has recently greatly promoted the development of natural language processing (NLP)
  • We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
  • We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
  • The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
  • Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined