Evaluation of the Quality and the Productivity of Neuroradiological Reading of Multiple Sclerosis Follow-Up MRI Scans Using an Intelligent Automation Software.

Neuroradiology(2024)

AI Medical AG

Cited 0|Views29
Abstract
Purpose The assessment of multiple sclerosis (MS) lesions on follow-up magnetic resonance imaging (MRI) is tedious, time-consuming, and error-prone. Automation of low-level tasks could enhance the radiologist in this work. We evaluate the intelligent automation software Jazz in a blinded three centers study, for the assessment of new, slowly expanding, and contrast-enhancing MS lesions. Methods In three separate centers, 117 MS follow-up MRIs were blindly analyzed on fluid attenuated inversion recovery (FLAIR), pre- and post-gadolinium T1-weighted images using Jazz by 2 neuroradiologists in each center. The reading time was recorded. The ground truth was defined in a second reading by side-by-side comparison of both reports from Jazz and the standard clinical report. The number of described new, slowly expanding, and contrast-enhancing lesions described with Jazz was compared to the lesions described in the standard clinical report. Results A total of 96 new lesions from 41 patients and 162 slowly expanding lesions (SELs) from 61 patients were described in the ground truth reading. A significantly larger number of new lesions were described using Jazz compared to the standard clinical report (63 versus 24). No SELs were reported in the standard clinical report, while 95 SELs were reported on average using Jazz. A total of 4 new contrast-enhancing lesions were found in all reports. The reading with Jazz was very time efficient, taking on average 2min33s ± 1min0s per case. Overall inter-reader agreement for new lesions between the readers using Jazz was moderate for new lesions (Cohen kappa = 0.5) and slight for SELs (0.08). Conclusion The quality and the productivity of neuroradiological reading of MS follow-up MRI scans can be significantly improved using the dedicated software Jazz.
More
Translated text
Key words
Intelligent automation,Machine learning,Artificial intelligence,Multiple sclerosis
PDF
Bibtex
收藏
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Related Papers
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper

要点】:本研究评估了智能自动化软件Jazz在多发性硬化症(MS)随访MRI扫描中的质量和效率,发现其能显著提高 neuroradiological 读取的质量和生产力。

方法】:通过三个独立中心,使用Jazz软件对117例MS随访MRI的FLAIR、术前和术后增强T1加权图像进行盲分析,并记录读取时间。

实验】:实验使用的数据集为117例MS随访MRI图像,结果发现使用Jazz软件描述的新病变数量显著多于标准临床报告,且无缓慢扩展病变(SELs)被报告,而Jazz平均报告95个SELs。读取时间平均为2分33秒,读取者间的总体一致性对新病变为中等(Cohen kappa = 0.5),对SELs为轻微(0.08)。