Spinal Cord Ischemia Following Simultaneous EVAR and TEVAR for Concomitant Thoracic and Abdominal Aortic Aneurysms.
Annals of Vascular Surgery(2022)
Northwell Hlth
Abstract
Background: In patients with abdominal aortic aneurysms, 10-20% has concomitant thoracic aortic pathologies. These are typically managed with staged endovascular aneurysm repair (EVAR) and thoracic endovascular aortic repair (TEVAR) due to a perceived higher risk of spinal cord ischemia from a simultaneous intervention. We aimed to determine the outcomes of pa-tients undergoing simultaneous EVAR and TEVAR for concomitant aneurysms.Methods: A retrospective cohort study was performed using the Vascular Quality Initiative reg-istry from December 2003 to January 2021. Patients undergoing same day EVAR and TEVAR were included and analyzed in accordance with the Society for Vascular Surgery reporting stan-dards. Primary outcomes were technical success and spinal cord ischemia.Results: Simultaneous EVAR and TEVAR were performed in 25 patients. Median age was 75.0 (interquartile range [IQR], 63.0-79.0) years and 20 (80.0%) patients were male. Two (4.0%) pa-tients were symptomatic and 4 (16.0%) presented with rupture. Median maximum infrarenal and thoracic aortic diameter was 57.0 (IQR, 52.0-65.0). Infrarenal aortic neck length was 15.0 mm (IQR, 10.0-25.0), and diameter was 27.0 mm (IQR, 24.5-30.0). Median procedure time was 185.0 min (IQR, 117.8-251.3), fluoroscopy time 32.7 min (IQR, 21.8-63.1), and contrast vol-ume 165 mL (IQR, 115.0-207.0). There were 3 (12.0%) Type Ia endoleaks and 3 (12.0%) Type II endoleaks in EVAR's, with 1 (4.0%) Type Ia and 1 (4.0%) Type II endoleak in TEVARs. In-hospital mortality occurred in 3 (12.0%) patients (1 elective, 2 ruptures). Spinal cord ischemia occurred in 1 (4.0%) patient. This patient had a symptomatic aneurysm. Thoracic coverage extended from Zone 4 to Zone 5 and an emergent spinal drain was placed postoperatively. Symptoms were present on discharge. There was 1 (4.0%) conversion to open repair which occurred in a ruptured aneurysm. Technical success was achieved in 19 (76.0%) patients, how-ever when excluding ruptured aneurysms, was achieved in 17 (81.0%) patients. Follow-up data was available for 19 (76.0%) patients at a median of 426.0 (IQR, 329.0-592.5) days postoper-atively. A total of 3 (12.0%) patients died during the late mortality period, at a mean of 509.0 (+/- 503.7) days. Median change in abdominal and thoracic aortic sac diameter was-1.35 mm (IQR,-11.5 to 2.5) and 8.0 (IQR,-10.5 to 12.0), respectively.Conclusions: Simultaneous EVAR and TEVAR for concomitant abdominal and thoracic aortic aneurysms can be performed with low rates of spinal cord ischemia. Short-and mid-term out-comes are acceptable.
MoreTranslated text
求助PDF
上传PDF
View via Publisher
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
- Pretraining has recently greatly promoted the development of natural language processing (NLP)
- We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
- We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
- The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
- Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example

Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined